Misdirected central venous catheter


Department of Anesthesia and Intensive Care, Jai Prakash Narayan Apex Trauma Center, All India Institute of Medical sciences, New Delhi-110 029, India

Click here for correspondence address and email

Date of Web Publication31-Mar-2010
 

How to cite this article:
D'souza N, Gupta B, Sawhney C, Chaturvedi A. Misdirected central venous catheter. J Emerg Trauma Shock 2010;3:209-10

How to cite this URL:
D'souza N, Gupta B, Sawhney C, Chaturvedi A. Misdirected central venous catheter. J Emerg Trauma Shock [serial online] 2010 [cited 2021 Jul 31];3:209-10. Available from: https://www.onlinejets.org/text.asp?2010/3/2/209/62100


Sir,

Central venous catheter (CVC) placement is a routine procedure in the management of critically ill patients. However, the placement of these catheters is not without risk. In the standard technique central venous cannulation is a blind procedure, which relies on the use of external anatomical landmarks. Correct placement of the CVC is an essential prerequisite for accurate monitoring of central venous pressure (CVP) and long-term use of the catheter. The complications of central venous cannulation are numerous and include malpositioning, a known complication with the reported incidence ranging widely from less than 1% to more than 60%. [1]

We present a case where the CVC was malpositioned in the contralateral subclavian vein. Right subclavian central venous access was performed in a 34-year-old critically ill tracheostomized patient in early sepsis with a 7 French triple-lumen catheter (BBraun) and fixed at the 16-cm mark at the skin level. On connecting the transducer to the monitor there was normal CVP waveform and free aspiration of venous blood. However, the chest roentgenogram revealed the tip of the central line to be seated in the contralateral side, i.e., in the left subclavian vein [Figure 1]. This malposition was unexpected as the pressure waveform was normal. The catheter was withdrawn 1½ cm and was subsequently radiographically confirmed to be in correct position.

Malpositioning of catheter tip in contralateral subclavian vein is an extremely unusual occurrence, although the incidence has not been stated clearly in studies. Other unusual catheter tip placements reported are in the left internal mammary vein, azygous vein, hemiazygos vein, lateral thoracic vein, inferior thyroid vein, left superior intercostal vein, thymic vein, pleural cavity, and the jugular foramen. [2],[3],[4] During subclavian vein catheterization, the most common misplacement of the catheter is cephalad, into the ipsilateral internal jugular vein (IJV).

After any repositioning of the CVC, chest radiography is required for confirmation. One study reported that manual occlusion of the ipsilateral IJV during subclavian vein cannulation reduced the chances of advancement of the CVC into the ipsilateral IJV. The IJV occlusion test (applying external pressure on the IJV for approximately 10 seconds in the supraclavicular area and observing the changes in the CVP and its waveform pattern) successfully detects misplacement of a subclavian vein catheter into the IJV. However, it does not detect any other misplacement. [3] Some authors implicate excessive lengths of guidewire as the cause. [4] Other authors consider the length of the CVC inserted itself to be a risk factor. Studies have hypothesized that the final position of the catheter tip depends on the course that the guidewire takes. This may be influenced by the initial orientations of the J-type guidewire tip during the subclavian approach. [5] We currently perform cannulations keeping the J-tip of the guidewire directed caudad and have found that this increases correct placement of CVC in the right atrium.

A 29% incidence of malposition was reported by Deitel and McIntyre in post-cannulation chest radiographs. [6] Misplacement of the catheter tip can enhance the risk of clot formation and cause thrombophlebitis and catheter erosion, apart from impairing CVP measurement. Moreover, malposition of a CVC in a small-caliber vessel can result in inaccurate readings and is also undesirable for hyperalimentation and other situations requiring long-term infusions. [7] Reinsertion of the catheters is not without potential complication and there is also the possibility of repeating the malposition.

Although radioimaging is the gold standard for confirming the correct positioning of the CVC, there may be a delay. The use of ultrasound (USG) to guide insertion of CVC is controversial. Some authors suggest that USG guidance improves the success rate of subclavian venous catheterization performed by relatively less experienced operators. On the other hand, others have reported that USG guidance had no effect on the rate of complications or failures of subclavian vein catheterization. [8] Hence, insertion of CVC remains essentially a blind procedure that is guided by anatomical landmarks.

We write this letter to reiterate the importance of careful radiological imaging as early as possible to verify correct placement of a CVC. The catheter tip could produce ideal central venous waveforms despite being seated at an undesirable site.

 
   References Top

1.Malatinský J, Kadlic T, Májek M, Sámel M. Misplacement and loop formation of central venous catheters. Acta Anaesthesiol Scand 1976;20:237-47.  Back to cited text no. 1      
2.Currarino G. Migration of jugular or subclavian venous catheters into inferior tributaries of the brachiocephalic veins or into the azygos vein, with possible complications. Pediatr Radiol 1996;26:439-49.  Back to cited text no. 2      
3.Ambesh SP, Pandey JC, Dubey PK. Internal jugular vein occlusion test for rapid diagnosis of misplaced subclavian vein catheter into the internal jugular vein. Anesthesiology 2001;95:1377-9.  Back to cited text no. 3      
4.Tsai YS, Huang JK, Cheng SJ, Fan YK. Malposition of a central venous catheter causing intracranial septic thrombophlebitis. Chin J Radiol 2006;31:109-13.  Back to cited text no. 4      
5.Tripathi M, Dubey PK, Ambesh SP. Direction of the J-tip of the guidewire, in seldinger technique, is a significant factor in misplacement of subclavian vein catheter: a randomized, controlled study. Anesth Analg 2005;100:21-4.  Back to cited text no. 5      
6.Deitel M, McIntyre JA. Radiological confirmation of the site of central venous pressure catheter. Can J Surg 1971;14:42-52.  Back to cited text no. 6      
7.Hofmann-Preiss K, Becker A, Sailer S. Radiologic and clinical follow-up of central venous indwelling catheters in home parenteral nutrition. Infusion Stherapie 1991;18:292-5.  Back to cited text no. 7      
8.Mansfield PF, Hohn DC, Fornage BD, Gregurich MA, Ota DM. Complications and failures of subclavian-vein catheterization. N Engl J Med 1994;29:1735-8.  Back to cited text no. 8      

Top
Correspondence Address:
Nita D'souza
Department of Anesthesia and Intensive Care, Jai Prakash Narayan Apex Trauma Center, All India Institute of Medical sciences, New Delhi-110 029
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0974-2700.62100

Rights and Permissions


    Figures

  [Figure 1]

This article has been cited by
1 Migration of subclavian venous catheter tip: Patient positioning in ICU makes a difference
SameerMahamud Jahagirdar,SameerMahamud Laxmimani,Umeshkumar Athiraman,M Ravishankar
Indian Journal of Critical Care Medicine. 2013; 17(3): 193
[Pubmed] | [DOI]
2 A low-cost reusable phantom for ultrasound-guided subclavian vein cannulation
Cheruparambath, V. and Sampath, S. and Deshikar, L.N. and Ismail, H.M. and Bhuvana, K.
Indian Journal of Critical Care Medicine. 2012; 16(3): 163-165
[Pubmed]
3 ECG-guided central venous catheterization - Can it truly detect internal jugular venous malpositioning of subclavian catheter
Jain, A. and Mangal, K.
Annals of Cardiac Anaesthesia. 2011; 14(1): 69-70
[Pubmed]



 

Top
 
  Search
 
  
  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Email Alert *
    Add to My List *
* Registration required (free)  


    References
    Article Figures

 Article Access Statistics
    Viewed3161    
    Printed120    
    Emailed3    
    PDF Downloaded42    
    Comments [Add]    
    Cited by others 3    

Recommend this journal