Journal of Emergencies, Trauma, and Shock
Home About us Editors Ahead of Print Current Issue Archives Search Instructions Subscribe Advertise Login 
Users online:3273   Print this pageEmail this pageSmall font sizeDefault font sizeIncrease font size   
ORIGINAL ARTICLE
Year : 2011  |  Volume : 4  |  Issue : 3  |  Page : 374-377

Indicators of potential for rupture for ectopics seen in the emergency department


1 School of Policy Studies, Roosevelt University, Chicago, IL, USA
2 Department of Emergency Medicine, Finch University/Chicago Medical School, Chicago, IL; Mount Sinai Hospital, Chicago, IL, USA

Correspondence Address:
La Vonne A Downey
School of Policy Studies, Roosevelt University, Chicago, IL
USA
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0974-2700.83867

Rights and Permissions

Background : Emergency departments (ED) frequently evaluate patients with probable ectopic pregnancies who go home and may rupture. It would be beneficial to know which patient factors are associated with rupture and which are not. Objectives : The purpose of this study was to determine which ED patients with ectopic pregnancies are at risk for rupture. Materials and Methods : This study was a retrospective chart review of all women aged ≥18 years during a 5-year period who were diagnosed with ectopic pregnancy to a level I ED. Data collected included basic demographic information, medical, surgical, obstetric and gynecologic history, social and sexual history, findings on physical examination, and laboratory values such as urine pregnancy test, b-hCG, and complete blood count. Results : There was a significant difference using a multivariate regression analysis with 95% CI in history findings of abdominal pain, nausea, vomiting, and urinary tract symptoms. There was a significant difference in physical examination of pulse, diastolic pressure, abdominal tenderness, peritoneal signs, cervical motion tenderness, and adnexal tenderness. There was also a significant difference in b-hCG, hemoglobin and hematocrit results and ultrasound findings of free peritoneal fluid, intrauterine pregnancy and cardiac findings between those who ruptured and those who did not. None of these tests was able to differentiate those that would go on to rupture. Conclusion : The result of the study did not find any single sign, symptom, or test that could reliably differentiate patients who have a ruptured ectopic from those who do not. However, b-hCG over 1500 mIU was the best variable in explaining the variation between those who would or would not go on to rupture after their ED visit.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2380    
    Printed176    
    Emailed0    
    PDF Downloaded18    
    Comments [Add]    
    Cited by others 2    

Recommend this journal