Emergency central venous catheterization revisited


1 Department of Anaesthesiology, G.S.V.M. Medical College, Kanpur, U.P, India
2 Department of Surgery, G.S.V.M. Medical College, Kanpur, U.P, India
3 Department of Obstetrics and Gynaecology, V.M.M.C and Safdarjung Hospital, N. Delhi, India

Click here for correspondence address and email

Date of Web Publication31-Aug-2009
 

How to cite this article:
Sahu S, Lata I, Sachan S, Singh R K. Emergency central venous catheterization revisited. J Emerg Trauma Shock 2009;2:218-9

How to cite this URL:
Sahu S, Lata I, Sachan S, Singh R K. Emergency central venous catheterization revisited. J Emerg Trauma Shock [serial online] 2009 [cited 2019 Dec 6];2:218-9. Available from: http://www.onlinejets.org/text.asp?2009/2/3/218/55348


Sir,

Internal jugular vein (IJV) catheterization is a fairly routine part of management of seriously ill patients and for the measurement of central venous pressure . In emergency department (ED) a resident doctor attempted to perform a right internal jugular vein canulation while managing a case of Carcinoma ovary. After cathertization the patient complained of respiratory distress and increasing chest discomfort. On examination, the patient was found to have decreased air entry in the right side of the chest and a dull note on percussion in the same side. frothy edematous fluid was aspirated through the central line port pink, came out. Suspecting misplacement of the catheter a chest X-ray was sought which showed a massive diffuse opacity in the right lung and incorrect position of the central catheter tip. The Right sided hydrothorax was managed by inserting a intercostals drain (ICD). This scenerio prompted us visit the topic of emergency central venous catheterization.

More than 5 million Central venous canulation (CVC) are placed each year in the United States, with an associated complication rate of >15%. Mechanical complications such as arterial puncture and pneumothorax are seen in up to 21%, and up to 35% of insertion attempts are not successful. [1],[2] The risk of complications depends on several factors, including (but not limited to) operator experience, urgency of placement, as well as patient factors such as obesity, prior difficult cannulation and coagulopathy. [3],[4] Moreover, accidental hydrothorax is more frequently associated with subclavian vein canulation and is a relatively uncommon in internal jugular vein canulation. Today the use of ultrasound has been associated with a reduction in complication rate and an improved first-pass success when placing catheters in the internal jugular (IJ) vein. From this case\ discussion, it would be prudent to remember that:-

  1. Only a medical practitioner having enough experience with central venous cannulation should perform this procedure.
  2. Aspiration of blood from the catheter port must always be done to confirm catheter placement in the right vessel.
  3. A post-procedural chest X-ray must always be ordered.
  4. Regular central venous pressure monitoring must be done.
  5. Patients' complaint of rapid onset chest discomfort and distress should always be attended.


Central venous access protocol

Line Sepsis is extremely serious and can be life threatening. All reasonable precautions must be followed to minimize sepsis rate. The following protocol is an inexpensive, effective system for placing new line and changing lines. [5]

  1. All equipment must be at hand, transducers calibrated and the monitors functional prior to starting. It is the residents' responsibility to be sure this is done prior to beginning. Do not open kit until you are ready to perform procedure and you are certain you have the correct catheter.
  2. Position the patient including placing EKG leads, supplemental oxygen and a pulse oximeter.
  3. Lower the side rail.
  4. Prepare the primary site and alternative site, usually the IJV and subclavian Vein using a 4 × 4 packs and Betadine.
  5. Wash hands. Put on a cap, mask, gown, and gloves.
  6. Open kit. Do a final prep with the prep sticks contained in the introducer or central access kit.
  7. Apply the small fenestrated sheet directly over the site.
  8. Apply the large fenestrated sheet contained in the universal access kit or a fenestrated utility sheet directly over the site. The field must be larger in all directions than the length of the wire. There should be no intravenous tubing hanging near the procedure site.
  9. Infiltrate Lidocaine.
  10. Place the patient in Trendelenburg position. In general, maximum Trendelenburg is used, but in some situations such as congestive heart failure, none is used.
  11. Gain access to the vein and using the Seldinger technique, dilate the track and place the catheter or introducer. Usual insertion distance is 15 cm. Use a sterile extension tubing to attach the side arm of the introducer or the CVC to the intravenous solution after anchoring the catheter in place. A needleless anchoring device is effective, available and may decrease needle injuries.
  12. Keep skin site sterile until final dressing is applied.
  13. An X-ray is required to confirm placement, and absence of pneumothorax.


So, by taking care of all the above reasonable precautions while putting CVC lines in ED one can minimize catastrophes and complications with increase quality of care and better patient outcome.

 
   References Top

1.Sznajder JI, Zveibil FR, Bitterman H, Weiner P. Bursztein S. Central vein catheterization: Failure and complication rates by three percutaneous approaches. Arch Intern Med 1986; 146:259-61.  Back to cited text no. 1      
2.Defalque RJ. Percutaneous catheterization of the internal jugular vein. Anesth Analg 1974; 53:116-21.  Back to cited text no. 2  [PUBMED]  [FULLTEXT]  
3.Goldfarb G, Lebrec D. Percutaneous cannulation of the internal jugular vein in patients with coagulopathies: An experience based on 1,000 attempts. Anesthesiology 1982; 56;321-3.  Back to cited text no. 3      
4.Mansfield PF, Hohn DC, Fornage BD, Gregurich MA, Ota DM. Complications and failures of subclavianvein catheterization. N Engl J Med 1994; 331:1735-8.  Back to cited text no. 4  [PUBMED]  [FULLTEXT]  
5.Bradley J. Phillips: Central Venous Access: A Protocol for Academic Medical Centres. The Internet Journal of Surgery. 2005. Volume 6 Number 1.  Back to cited text no. 5      

Top
Correspondence Address:
Sandeep Sahu
Department of Anaesthesiology, G.S.V.M. Medical College, Kanpur, U.P
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0974-2700.55348

Rights and Permissions



This article has been cited by
1 Silver nanoparticles-modified films versus biomedical device-associated infections
Huiliang Cao, Xuanyong Liu
Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology. 2010; 2(6): 670
[VIEW] | [DOI]



 

Top
 
  Search
 
  
  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Email Alert *
    Add to My List *
* Registration required (free)  


    References

 Article Access Statistics
    Viewed2614    
    Printed123    
    Emailed0    
    PDF Downloaded89    
    Comments [Add]    
    Cited by others 1    

Recommend this journal